I got this to replace a 50a55-480 controller for my Trane furnace (TDE080).
I got it instead of the cheaper 50a55-843 for 2 reasons:
1) It drives newer Silcon Nitride ignitors which are supposed to be more reliable than the older silicon carbide ignitors. It will also drive your existing silicon carbide ignitor.
2) This kit also includes an ignitor, worth about $25. I keep it as a spare until my SiC ignitor fails.
Installation is easy using the supplied instructions, but there are a few things to note:
1) The unit mounts to the same clips as the 50a55-480, but is about 1/2 inch wider on the left side (with LED).
2) The indicator LED is in a different place, so I had to drill a new 1/4" hole in the furnace to be able to see the light from the outside.
3) The harness adapter (F) works fine and provides a spade clip for the Flame Sensor. Also be sure to install the rollout jumper between pins 5 and 11. Trane furnaces don't have rollout sensors. I preferred to skip the adapter and do a little minor surgery to attach a spade clip directly to the flame sensor wire. The gas valve connection is OK as long as the controller is configured for a single-stage furnace.
4) When the thermostat's Fan-ON switch is set, most controllers enable the cool-H fan terminal. However, this controller enables the Heat-L terminal. You should connect a "parked" (red, blue, yellow) fan lead to Heat-L, or if you don't have air conditioning, connect the black cool-H lead to the Heat-L terminal instead.
5) As mentioned in a previous review, all of the 6 neutral spades are connected together, so it doesn't matter which ones you use. To be extra nerdy, put the incoming line-N on a center terminal and Fan-N and Xfrmr-N on the adjacent terminals.
Click Here For Most Helpful Customer Reviews >>
This was to replace a obsoleat one, the wireing instruction could have been more expliced to the one it is to replace.I wouldn't have had to call in the HVAC guy, to be sure I had it right. It works the air, now if it works the heat and the humidifier in the heating season, the I'll upgrade my rateing to "Love IT", cause I sure saved a lota money.